SK
A large PV plant seen from above

Solar PV Underperformance

How much PV loses, why, and what it costs.

0,95
median lifetime performance index, i.e. 5% below the model
NREL, 2024 · 1,128 systems, 8.5 GW
7–13 %
underperformance against the P50 model for projects after 2015
kWh Analytics, 2022
5,08 %
power loss from equipment faults in 2025. In 2021 it was 2.36%.
Raptor Maps, 2026
79 %
high-risk connector faults with no thermal signature
kWh Analytics, Solar Risk Assessment 2026
3,36 %
of modules failed pre-shipment inspection. A record high.
Kiwa PI Berlin, 2026
76 of 774
module batches passed inspection without a single defect
Kiwa PVEL / PI Berlin, 2024
+70 %
installed capacity per service technician compared with five years ago
Raptor Maps, 2026
34,3 %
of residential inverters have a first fault within 15 years
Bucher et al., BFH, 2022

“The difference between segments is not that smaller installations have more faults. It is that nobody knows how many they have.”

Solar PV Underperformance 2026, section 8.2

30 years of operation: management decides, not technology

A reference 100 kWp plant on an industrial hall roof. The three scenarios differ only in how the plant is managed.

A — actively managed B — managed to a standard level C — neglected

Underperformance against the investment model with 0.5%/year degradation. The model does not include a one-off outage for inverter replacement. Scenario C is an extrapolation.

What it costs over the whole lifetime

Value of unproduced energy over 30 years at 100 kWp and €0.11/kWh. The difference between active and neglected management is roughly €54k.

Study, section 6.2.

More frequent inspection, smaller loss

The strongest data point in the study. A difference of about 4 percentage points is the best available estimate of how much of the loss can be fixed.

Raptor Maps, Global Solar Report 2026. Correlation, not proven causation.

Why nobody sees the faults

Free monitoring from the inverter manufacturer reliably catches only a minority of causes of loss. Most faults do not look like faults in it.

ProblemFrequencySeverityDoes inverter monitoring see it?
Inverter outageHighHighYes
String outageHighMedium–highPartly
Connector and DC cabling faultHighMediumNo
SoilingVery highLow–mediumNot without a model
Gradual shadingMediumMediumNot without a model
MicrocracksHighLow, risingNo
Hot spotMediumMedium, safety-relatedNo
PIDLow–mediumHighPartly
Faulty bypass diodeMedium, risingHigh, safety-relatedNo
Incorrect settings at commissioningMediumMediumNot without a model

Study synthesis, section 5.5.

A 250 kWp plant in numbers

Underperformance reduces revenue linearly, but fixed costs remain. At a CAPEX of €600/kWp.

IndicatorNo losses5% underperformance10% underperformance15% underperformance
Annual output275 MWh261.3 MWh247.5 MWh233.8 MWh
Annual loss—1 513 €3 025 €4 538 €
Simple payback5.0 years5.2 years5.5 years5.8 years
25-year loss—€37.8k€75.6k€113.4k

Undiscounted, excluding operating costs. An illustration of scale, not a financial model of the project.

SourcesNREL PV Fleet Performance Data Initiative · IEA PVPS Task 13 · Raptor Maps Global Solar Report 2026 · kWh Analytics Solar Risk Assessment 2026 · Kiwa PI Berlin · SolarPower Europe · ERÚ

Detail of a PV panel

How much is your plant losing?

We compare actual output with expected output and show what is worth repairing.