SE

Our softwareParhelion

How Parhelion works

Parhelion works with the data your plant already collects. Nothing is installed and nobody has to go up on the roof.

  1. Output from the inverter

    We take output from the inverter portal you already have. No new hardware and no intervention in the plant.

  2. Satellite and weather

    For the exact plant location we add solar irradiance, cloud cover, temperature and wind from satellite and weather data.

  3. Digital twin

    A physical model of your plant calculates at every moment how much it should produce. It learns from the production history, so it recognises morning shade from a chimney or an inverter limiting output in summer, and does not report such normal behaviour as a fault.

  4. Statistics and neural network

    We compare every string with the model and with neighbouring strings that see the same weather. A cloud affects all of them equally, so only a real loss stands out. A neural network finds patterns a person would miss and tells a random fluctuation from a lasting problem.

  5. Finding

    Where the loss is, how many kWh and how much money it costs, its probable cause and what to do. After the repair, Parhelion checks by itself that output has come back.

How we build the digital twin

Every plant gets a different model. We build it from the plant’s parameters and fine-tune it on its history.

  1. Plant geometry

    Location, panel tilt and orientation, number of modules, string layout and inverters. Without documentation, we derive them from the production record.

  2. Physical model

    It converts the irradiance on the panels, their temperature and the losses in cabling and inverters into the output of each string.

  3. Calibration on history

    When we connect the plant, we compare the model with its production history. We adjust its parameters, correct the satellite data offset for the site and teach it the shading and inverter limits.

  4. The finished twin

    For every string, at every moment, it knows what it should have produced. Every finding starts from this number.

Calibration

Every plant behaves a little differently. One has morning shade from a chimney, another has an inverter that cuts output in summer. The model learns this from the production history. That makes it more precise, so it also catches small underperformance that a generic model would miss.

Actual outputGeneric modelCalibrated twin

Loss breakdown

We split the gap between expected and actual output into downtime, shading, soiling, temperature and string faults. You see the estimated loss in kWh for each item.

−4,160 kWh−2,688 kWh−1,984 kWh
ExpectedDowntimeShadingSoilingInverter heatString faultActual

Small losses, caught early

Basic monitoring alerts you when an inverter goes down or output drops sharply. Parhelion compares every string with the model, so it also catches a few percent that would otherwise go unnoticed.

12345678Month Basic monitoring Parhelion
Production loss

What to fix first

A thermal drone inspection shows where a plant has a defect. It does not tell you what it costs. Parhelion combines the inspection findings with production data. For every defect it calculates the real loss in kWh and money and ranks repairs by priority.

Inspection findings

  1. INV-03 / STR-D4 / MC4

    Increased contact resistance

    The MC4 connector is 45 °C warmer than the others. The energy loss is small, but it is a fire risk.

    Loss
    60 kWh/yr
    Cost
    Safety risk
    Priority
    Critical

    RecommendationReplace the connector immediately.

  2. INV-02 / STR-C2 / M01–M08

    PID degradation

    Thermal imaging shows higher module temperatures at the negative end of the string. Output is 11% below comparable strings and the gap is growing.

    Loss
    990 kWh/yr
    Cost
    €160/yr
    Priority
    High

    RecommendationPID regeneration, or module replacement if needed.

  3. INV-01 / STR-A5 / M03, M11, M17

    Shorted bypass diodes

    On three modules, one third of the cells is permanently out of action. The string loses about 5% of its output.

    Loss
    450 kWh/yr
    Cost
    €70/yr
    Priority
    Medium

    RecommendationReplace junction boxes or modules under warranty.

  4. INV-01 / STR-B1 / M07

    Hot spot, cracked cell

    One cell is 28 °C warmer than its surroundings. The loss is small so far, but as the temperature rises the module may be damaged.

    Loss
    120 kWh/yr
    Cost
    €20/yr
    Priority
    Medium

    RecommendationReplace the module and file a warranty claim.

Reports

Monthly and annual report: availability, performance ratio, output against plan and losses by cause. As a PDF, or as data in Power BI and through the API.

Availability99,4%
Performance ratio84,1%
Output against plan97,2%
Irradiation1,112 kWh/m²
JanFebMarAprMayJunJulAugSepOctNovDec

Three steps, no new hardware

  1. We connect the data

    Read-only access to the inverter portal.

  2. Parhelion builds the twin

    It learns how your plant runs.

  3. We send reports

    Findings, losses and production forecast in the portal and in a regular report.

Close-up of a solar panel

Where Parhelion is heading

From watching output to a plant that looks after itself.

  1. Foundation

    Monitoring

    You see how much the plant produced.

  2. Parhelion

    Diagnostics

    You know where and why the plant loses output and what it costs.

  3. Parhelion

    Automation

    Findings, tasks and reports are created automatically, without manual work.

  4. Parhelion

    Optimisation

    Repairs and maintenance are planned by what brings back the most energy.

Systems we connect

Data

  • Manufacturer cloudinverters of all major brands
  • API and data loggersexisting equipment stays
  • Satellite weatherirradiance and temperature at your site
ParhelionOne portal for every plant and brand. No new hardware.

Outputs

  • Faultscommunication loss, disconnected inverter
  • Low productionagainst expected output
  • Customer reportsa PDF for every installation
  • Power BI and APIdata for your own analysis

Inverters

  • Huawei
  • SMA
  • Sungrow
  • Fronius
  • SolarEdge
  • GoodWe
  • Solis
  • Growatt
  • Deye
  • Enphase
  • ATMOCE
  • Hoymiles
  • APsystems
  • Fox ESS
  • SolaX
  • Sofar
  • Kostal
  • Victron Energy

Manufacturer clouds and monitoring

  • SOLARMAN
  • FusionSolar
  • Sunny Portal
  • iSolarCloud
  • Solar.web
  • SEMS Portal
  • SolisCloud
  • Enphase Enlighten
  • meteocontrol
  • Solar-Log
  • SCADA
  • Modbus TCP

Data and reports

  • Power BI
  • REST API
  • PDF reports
  • CSV and Excel

Using a different system? Write to us and we will check the connection.

Parhelion and ordinary monitoring

What a standard inverter portal tells you, and what Parhelion adds.

Basic monitoringParhelion

Output

Total for the plantPer string, where the inverter measures it

What the plant should have produced

UnknownFrom the calibrated model

Loss in money

UnknownFor every finding

Cause and location of a fault

Outages onlyProbable cause and string

Repair cost and payback

UnknownCalculated in advance

How the loss develops

UnknownForecast of its growth

Check after repair

ManualAutomatic, against the model

Repairs and warranty claims

Up to youHandled by the Sunalytiq team

Frequently asked questions

Do we need to install anything for Parhelion?

No. We take the data from the inverter manufacturer’s cloud or through an API. Inverters and data loggers stay as they are. Weather comes from satellite data.

How reliably does Parhelion find faults?

In blind tests on real plant records, it found 97% of inverter outages, mostly on the same day. It caught a 2% drop in string output within 8 weeks in 9 out of 10 cases.

Does it work with our inverter?

We connect to the major inverter brands and manufacturer clouds. The list is above under Supported systems. If your system is not there, write to us and we will check the connection.

We have no technical documentation. Is that a problem?

No. Parhelion works out the tilt, orientation and size of the plant from its production record. Documentation makes the model more precise, but you can start without it.

How long does it take to start?

Connecting the data usually takes a few days. Then we calibrate the model on the production history. You get the first results within four weeks.

Who will see our data?

Only authorised people from the Sunalytiq team and those you give access to. We do not sell data, and a service company only receives the description and location of a fault. Details are in our privacy policy.

How much does it cost?

We price it by plant size or number of installations and the scope of services. Book a consultation and we will send you a quote.

Parhelion

Build a digital twin of your plant

  • No new hardware
  • Connection to your inverter
  • Findings down to individual strings